Need to chat, call us on 1800 224 234

Viol

Sylfirm X

Dual-wave RF microneedling device.

Treat skin laxity, rosacea, acne, scarring and dermal pigment with a single device.

Viol

Sylfirm X

Dual-wave RF microneedling device.

Non-invasive and versatile skin rejuvenation
Customizable treatments for individual patient needs
Minimal patient downtime
Significant improvement in skin texture and firmness

Sound familiar?

Your clients present with vascular concerns, pigmentation changes, and early signs of skin laxity, often in the same consultation. Most single-modality devices force you to choose which concern to prioritise, or require multiple platforms in the room. With Sylfirm X, you can deliver want visible improvement to multiple concerns, without extended downtime.

What does it do?

The Sylfirm X is a dual-wave RF microneedling system that delivers both continuous-wave and pulsed-wave radiofrequency through non-insulated gold-plated needles.

It operates across 8 modes with 38 adjustable depths starting from a world-first 0.3mm, allowing treatment within the papillary dermis.

The non-insulated tip design improves RF energy delivery, making the treatment significantly more comfortable than comparable devices and reducing the number of clients who pause or discontinue treatment.

Technical Specifications

  • System Type: RF (Radiofrequency)
  • Power Input: AC 100~240V, 50/60Hz
  • Electrode Depth: 2 Mhz.
  • Mode: 8 Modes. CW(Continuous Wave) 1~4. PW(Pulsed Wave) 1~4.
  • Max Power: 0~12 Level. (0: Minimum, RF OFF) (1-12: Maximum, RF ON)
  • Speed: 0.1~1 sec (0.1sec step)

In The Treatment Room

For a clinic looking to move into device-based skin treatments or expand an existing skin menu, Sylfirm X reduces the need for multiple devices in the room. Treatment courses typically run across multiple sessions, which builds consistent rebooking revenue. The range of treatable concerns also means you can offer combination treatment plans tailored to each client, increasing the average value per client relationship.

RF Microneedling: Skin tightening and texture improvement with minimal downtime. Results build over the treatment course, creating strong rebooking patterns.

Rosacea and vascular treatment: The pulsed-wave mode targets vascular concerns in the papillary dermis.

Melasma management: Controlled energy delivery at shallow depths enables melasma treatment with a lower risk of post-inflammatory hyperpigmentation. A notoriously difficult condition that clients will travel for if they find a clinician who treats it well.

Skin rejuvenation: Overall improvement in skin tone, texture, and firmness. A strong entry treatment that introduces new clients to your clinic’s device-based services.

Scar revision: Treat acne scarring and surgical scars. Often, a gateway service that leads clients into broader skin rejuvenation programs.

Stretch mark reduction: An additional treatment offering that expands your client base beyond facial concerns.

Flexible device plans

Subscribe

Clinical training, device servicing, repairs, 48-hour engineer dispatch, dedicated account manager, business support, and 7-day support access. Weekly fee via direct debit.

Subscribe-to-Own

Clinical training, device servicing, maintenance coverage, dedicated account manager, business support, and 7-day support access. Weekly payments over 2 or 3 years. The device is yours upon completion of your term. 

Own

Clinical training, manufacturer warranty, marketing collateral, dedicated account manager, 7-day support access, and online store access. Full payment before delivery. We offer service contracts as add-ons. 

Frequently asked questions

The Sylfirm X treats rosacea, melasma, skin laxity, scarring (including acne scars), stretch marks, wrinkles, and general skin rejuvenation. The dual-wave system with 8 modes and 38 adjustable depths allows you to customise treatments for a wide range of presentations from a single platform.

The Sylfirm X uses non-insulated gold-plated tips, which improve RF energy delivery and make the treatment significantly more comfortable than insulated-needle alternatives. It’s also the world’s first device to offer 0.3mm depth, allowing treatment within the papillary dermis. The 38 adjustable depths in a single tip give you more control over each treatment than devices with fixed depth settings.

Yes. The Sylfirm X uses “colourblind” pulsed radiofrequency technology that targets vascular and pigmentation concerns without relying on skin chromophores, making it safe and effective across all Fitzpatrick skin types (I-VI). The controlled, non-insulated needle technology minimises the risk of post-inflammatory hyperpigmentation (PIH), which is a common concern with energy-based treatments on darker skin tones (Fitzpatrick IV-VI). The device is also well-suited for sensitive skin and conditions like rosacea. For clients with Fitzpatrick type IV or higher, using a tyrosinase inhibitor and SPF for at least 2 weeks before treatment is recommended to ensure maximum safety.

Most clients require 4 to 6 sessions, depending on the treatment area and their goals. Sessions are spaced 2 to 4 weeks apart. Your clinical trainer will cover how to structure treatment courses for different indications during your training.

The Sylfirm X uses single-use tips that are individually sealed to prevent infection. Each tip resets automatically with every shot, ensuring consistent energy delivery across the treatment. Tips are available through the Laseraid online store.

Yes. The Sylfirm X pairs well with LED therapy (such as the OptiGlow LED), and complements laser platforms for clinics offering a full skin treatment menu. Your clinical trainer can help you develop combination treatment protocols.

Want to see how the Sylfirm X fits your clinic?
Talk to our team about booking your demo.

Download your device brochure

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Name*

We're closed for the holidays

Laseraid will be closed from December 22nd to January 8th. For service queries during this time, email service@laseraid.com.au or call 1800 224 234 (select option 2). For general device or account enquiries, email enquiries@laseraid.com.au. We'll get back to you when we return on January 8th.

For online store queries, email orders@laseraid.com.au.